Product
Recommended article
- Meteorological observation station Observes Localized Meteorological Data
- DC power supply is used for photovoltaic module defect detection
- Five-in-One Weather Station for 24-Hour Continuous Monitoring of Outdoor Meteorological Parameters
- Odor gas detector is used for precise odor monitoring in multiple scenarios
- Six-Element Weather Station: Precise Monitoring of Basic Meteorological Elements, Adaptable to Multiple Industries
- Odor Monitoring System is widely used in various odor pollution sources
Contact us
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

SO2 sensor
Model:FT-QT2S
Brand:fengtu
Related products
1. Technical parameters of SO2 sensor
SO2 sensor is used to monitor the concentration of sulfur dioxide and is suitable for gas concentration detection in various industrial environments and special environments.
| model | Measurement parameters | Measuring range | Accuracy | Resolution | unit | Operating temperature | Operating humidity |
| QT1 | Carbon monoxide | 0-1000PPM | ±2PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT1S | 0-20PPM | ≤±5% | 0.01PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT2 | Sulfur dioxide | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT2S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT3 | Nitrogen dioxide | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT3S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT4 | ozone | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT4S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT5 | Oxygen content | 0~30%VOL | ±3%FS | 0.1%VOL | VOL | -20℃-+50℃ | 5-95%RH non-condensing |
| QT6 | Negative oxygen ions | 0~100,000/cm³ | ±10% | 10pcs/cm³ | Pieces/cm³ | +10℃-+70℃ | 10-70%RH without condensation |
| QT7 | Hydrogen sulfide | 0-100PPM | ±2PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT8 | Methane | 0-100%LEL | ≤±3% | 1%LEL | LEL | -20℃-+50℃ | 10-95%RH non-condensing |
| QT9 | TVOC | 0-100PPM | 55±15 nA/ppm | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT10 | Ammonia | 0-100PPM | ±4PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT11 | Nitric Oxide | 0-250PPM | -2~10PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT12 | formaldehyde | 0-10PPM | <1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
2. SO2 sensor product dimensions

Related article
-
Radar speed gun with Printing Function for Mobile Speed Enforcement
2026-01-27 -
The 5 - Element Small Automatic Weather Station: Compact, Practical & Multifunctional
2025-03-18 -
System framework for digital weather stations
2024-05-10 -
Automated systems for meteorological stations
2024-04-18 -
Combatting Dust: The Role of Dust Monitoring Equipment in Protecting Air Quality
2025-01-02 -
Temperature, humidity, visibility, wind, icing, haze monitoring equipment
2024-06-17 -
What are the five elements of weather testing equipment?
2024-07-18 -
What are air quality monitoring stations?
2024-06-06


Get a Free Quote