- The miniature weather station equipment outputs twelve monitoring data points simultaneously via a digital interface
- Atmospheric electric field meters provide early warnings of thunderstorm activity by monitoring changes in the ground electric field
- Real-time data from the road meteorological monitoring system supports traffic early warning
- photovoltaic testers can test photovoltaic strings up to 30kW
- Weather monitor Enables Rapid Field Deployment Through High Integration and Low Power Consumption Design
- Power Quality Measurement How to Detect Power Grid Waveform Distortion and Harmonic Content?
Contact us
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Sulfur dioxide sensor
Model:FT-QT2
Brand:fengtu
Related products
1. Technical Parameters of Sulfur Dioxide Sensor
Sulfur dioxide sensor continuously monitors the concentration of sulfur dioxide sensors and transmits the data to the monitoring system.
| model | Measurement parameters | Measuring range | Accuracy | Resolution | unit | Operating temperature | Operating humidity |
| QT1 | Carbon monoxide | 0-1000PPM | ±2PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT1S | 0-20PPM | ≤±5% | 0.01PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT2 | Sulfur dioxide | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT2S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT3 | Nitrogen dioxide | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT3S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT4 | ozone | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT4S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT5 | Oxygen content | 0~30%VOL | ±3%FS | 0.1%VOL | VOL | -20℃-+50℃ | 5-95%RH non-condensing |
| QT6 | Negative oxygen ions | 0~100,000/cm³ | ±10% | 10pcs/cm³ | Pieces/cm³ | +10℃-+70℃ | 10-70%RH without condensation |
| QT7 | Hydrogen sulfide | 0-100PPM | ±2PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT8 | Methane | 0-100%LEL | ≤±3% | 1%LEL | LEL | -20℃-+50℃ | 10-95%RH non-condensing |
| QT9 | TVOC | 0-100PPM | 55±15 nA/ppm | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT10 | Ammonia | 0-100PPM | ±4PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT11 | Nitric Oxide | 0-250PPM | -2~10PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT12 | formaldehyde | 0-10PPM | <1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
2. Sulfur dioxide sensor product dimensions

Related article
-
Fengtu Agricultural Meteorological Stations,Climate-Smart Farming
2024-08-19 -
Introduction to the micro ambient air quality monitoring station equipment
2024-07-01 -
Power Quality Measurement How to Detect Power Grid Waveform Distortion and Harmonic Content?
2026-05-27 -
Natural Oxygen Bars in Scenic Spots: Negative Ion Monitoring for Healthy Tourism Development
2025-06-18 -
Vehicle-Mount Weather Stations: Mobile Solutions for Environmental Monitoring and Air Quality Analysis
2025-05-26 -
Substation micrometeorological environment monitoring
2024-06-18 -
How Tunnel COVI Detectors Protect Driving Safety in Real Time
2026-05-21 -
Mobile Weather Stations: Versatile Tools for Meteorological Monitoring
2024-10-15