Product
-
Weather station
-
Road Weather Station
-
Photovoltaic Inspection
-
Atmospheric monitoring
-
Operating condition monitoring
Recommended article
- The miniature weather station equipment outputs twelve monitoring data points simultaneously via a digital interface
- Atmospheric electric field meters provide early warnings of thunderstorm activity by monitoring changes in the ground electric field
- Real-time data from the road meteorological monitoring system supports traffic early warning
- photovoltaic testers can test photovoltaic strings up to 30kW
- Weather monitor Enables Rapid Field Deployment Through High Integration and Low Power Consumption Design
- Power Quality Measurement How to Detect Power Grid Waveform Distortion and Harmonic Content?
Contact us
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

EL series of DC power supply
Model:FT-150030
Brand:fengtu
Related products
1.EL series of DC power supply product introduction
EL series of DC power supply meets the high voltage requirements of EL testing with high output voltage.EL series of DC power supply is developed by our company for the reverse power-on characteristics of photovoltaic power station strings. It converts AC power into DC power and inputs it into the solar panels to stimulate electroluminescence, thereby conducting internal defect tests on EL.
FT-150030 is a research and development type program-controlled power supply, which controls the electrical performance and safeguards of EL series of DC power supply through program software system. Its pro version is a high-quality software configuration, using higher quality imported electronic components with open programming host, which can better guarantee the stability and safety of string detection.
2. Technical parameters of EL series of DC power supply
1. ELEL series of DC power supply for photovoltaic
| Specification | FT-150030 | FT-150050 | FT-150010 |
| Power parameters | 0~1500V; 0~3A | 0~1500V; 0~5A | 0~1500V; 0~10A |
| quality | Programmable linear domestic | Program-controlled custom import | Program-controlled custom import |
| Scenes | EL detector single block/string test | EL detector single block/string test | EL detector + drone EL test |
| Voltage output | 0~1500V | 0~1500V | 0~1500V |
| Voltage accuracy | 1V | 0.001V | 0.001V |
| Compensation voltage | 12V | 96V | 96V |
| Current output | 0~3A | 0~5A | 0~10A |
| Current accuracy | 0.1A | 0.001A | 0.001A |
| Power accuracy | ±0.1A; ±1V | ±0.001A; ±0.001V | ±0.001A; ±0.001V |
| Power Output | 0~4.5KW | 0~8KW | 0~16KW |
| Power stability | ±0.1% | ±0.002% | ±0.002% |
| Output accuracy | ±0.1% | ±0.001% | ±0.001% |
| Output efficiency | >80% | >95% | >95% |
| Output Line Regulation | ±0.5% | ±0.005% | ±0.005% |
| Output load regulation | ±0.5% | ±0.005% | ±0.005% |
| Input voltage | 220VAC | 380VAC | 380VAC |
| Input frequency | 50/60Hz | 50/80Hz | 50/100Hz |
| Input Power Factor | >0.75 | >0.5 | >0.5 |
| Power-on time | Manual control | Program-controlled timing automatic power on and power off | |
| Insulation withstand voltage input to output | 2500VDC | ||
| Insulation withstand voltage output to shell | 500VDC | ||
| OVP adjustment range | 0-100% front panel adjustment (or digital interface) | ||
| OVP regulation accuracy | ±1% rated value | ||
2. ELEL series of DC power supply/programmable control system
| Specification | FT-150030 | FT-150050 | FT-150010 |
| Programmable control system | Control current and voltage output and monitor power supply working status | The program control panel can directly set various program control indicators of the power supply | |
| Programmable remote interface | RS-485C, analog interface (0-10V) | ||
| Programmable control panel | - | The power panel can be programmed to control the power on and off time, timed power on, protection threshold, etc. | |
| Reverse current protection | - | The reverse current impedance threshold can be set to prevent string current backflow | |
| Short circuit protection | PV string reverse connection short circuit protection to prevent PV module diode breakdown | ||
| Program-controlled buffer protection | - | Cache-type photovoltaic groups are disconnected in series to prevent large currents from directly penetrating the photovoltaic panels | |
| Program-controlled steady-state output | - | Adaptively match current and voltage according to different power components in the string (avoid breakdown of component diodes) | |
| Digital voltage programming accuracy | - | ±0.001% | ±0.001% |
| Digital current programming accuracy | - | ±0.001% | ±0.001% |
| Programmable rise time | - | 0~10s can be set | |
| Programmable fall time | - | 60ms (no load); 250ms (load 10%); 2.5s (full load) | |
| Voltage fluctuation control | 0.1V/ms~10V/ms | 0.001V/ms~0.002V/ms | |
| Current fluctuation control | 0.1A~0.2A | 0.001A~0.01A, or 1NF | |
| Minimum time for fluctuation control | 5ms | 0.1ms | |
| Panel Display | Digital display insulation control panel | Host control panel | |
| Panel Control | - | The power supply current and voltage protection limit value OVP can be set | |
| Photovoltaic EL power-on characteristics | High and low current switching test (manual switching) | High and low current switching test (programmed automatic switching) | |
| Number of components powered on simultaneously | Can simultaneously complete the detection and power supply access of 1 to 32 photovoltaic panels (within 1500V) | ||
| Photovoltaic power access port | Combiner Box / Inverter / String Port / Module Port | ||
| Steady-state output module | - | Stable power-on: The power parameters of each component in the string are consistent on average (to prevent photovoltaic panel breakdown) | |
| Constant temperature control module | Air cooling for continuous heat dissipation and temperature control | Electronic temperature control at 45°C ensures 24-hour uninterrupted operation | |
| Overload protection | - | The overload threshold can be set, and the output will stop automatically when overloaded to prevent the power supply transformer from being burned. | |
| Output short circuit automatic protection | Protect against power failure and personal danger caused by power station line or component string disconnection, and the power supply is automatically cut off | ||
| Input voltage automatic protection | - | Can protect power supply components from burning out due to excessive input voltage fluctuations | |
| Phase loss protection | Can protect against power damage and accidents caused by three-phase circuit breaker | ||
| Internal overheat protection | Dynamically dissipate heat according to the internal temperature to ensure that the power supply will not burn out due to overheating | ||
| High voltage isolation protection | Ensure the safety of high voltage electrical work for operators of the whole machine casing and panel | ||
| Input Line | 2 meters (6 square meters) | ||
| Wiring | AC220 | Three-phase three-wire + ground wire | |
| volume and weight | 430x88x450mm; 13kg | 17kg | 26kg |
Note: EL series of DC power supply is a high-power DC output power supply, which is a high-voltage equipment. The program control system is customized for photovoltaic power station scenarios, which can better ensure the safety of on-site manual construction. However, high-voltage equipment is still a high-risk equipment. Please strictly follow the operating instructions and standardize wiring and operation. In the event of power protection, contact the manufacturer as soon as possible to solve the problem. Do not operate the wiring without authorization to prevent danger! ! !
Related article
-
Introduction to forest security monitoring systems
2024-04-12 -
What is Weather Station, and what are its functions?
2025-11-28 -
Handheld Laser Cloud Meter FT-YG2 Introduction
2024-05-07 -
Power Quality Monitoring Equipment multi-channel measurement instrument meets the monitoring needs of power systems
2026-05-22 -
Automated Monitoring for Geological Disasters: Solutions for Hazard Point Detection and Early Warning
2025-06-13 -
I-V Curve Tracer: Principles, Instrumentation and PV System Applications
2025-10-13 -
How PV Weather Station Optimizes Photovoltaic Power Generation and Management
2024-11-28 -
Why Small Automatic Weather Station Stands Out: Monitoring, Configuration & Practicality
2025-09-10


Get a Free Quote







