Product
-
Weather station
-
Road Weather Station
-
Photovoltaic Inspection
-
Atmospheric monitoring
-
Operating condition monitoring
Recommended article
- Electrical Power Analyzer enables multi-channel power grid parameter acquisition and the detection of harmonics and unbalance
- Shandong Fengtu, a manufacturer of meteorological stations, offers high-precision weather observation equipment designed for field use
- Series power supply for EL-Based Internal Defect Detection in Photovoltaic Modules
- Shandong Fengtu, a manufacturer of meteorological monitoring instruments, produces advanced weather observation equipment
- Odor gas detector On-site Monitoring of Odorous Pollutants in Compliance with the GB14554 Standard
- Integrated Four-Parameter Weather Station for Field Meteorological Data Collection (Temperature, Humidity, Wind Speed, and Wind Direction)
Contact us
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

inhalable dust sampler
Model:CCZ20
Brand:fengtu
Related products
Inhalable dust sampler technical parameters:
inhalable dust sampler is used to collect total dust and exhaled dust in the air environment. It uses the filter weighing method to capture inhalable particles (PM10) in indoor air.
1.Sampling flow rate: 5-30 L/min, 5-25 L/min, 10-25 L/min, 1-10 L/min (flow rate optional) Respirable dust sampling flow rate: 20 L/min
2.Sampling flow error: ≤±3%FS
3.Sampling flow stability: sampling flow stability of the sampler within 60 minutes ≤ 3.0% FS
4.Load capacity: ≥200Pa
5.Continuous working time: ≥100min
6.Working noise: ≤75dB(A)
7.Flow meter accuracy: not less than level 2.5.
8.Sampling time error: ≤±0.1% within 5 minutes
9.Average flow rate at sampling port: 0.5~4.0m/s
10.Air tightness: The sampling head and flow meter of the sampler are kept under a pressure difference of (1000-1100) Pa for 1 minute, and the pressure change shall not exceed 100 Pa.
11.Ambient temperature: -10~40℃ Relative humidity: ≤95%
12.Explosion-proof type: Mining intrinsically safe type ExibI (150°C), suitable for flammable and explosive workplaces and underground sampling in coal mines.
13.Intrinsically safe battery pack: Use Ni-H nickel-metal hydride batteries 2.7A/h, 6 cells, 4 0.51Ω/10W current limiting resistors in series, encapsulated with epoxy resin and placed in the battery box, rated voltage Ue: 7.2V; its maximum output voltage U0: 9.0V; maximum output current I0: 4.52A.
14.Overall dimensions: 149×202×80 (mm)
15.Weight ≤ 1.75Kg
16.Ambient temperature: 0~40℃ Relative humidity: ≤95%
17.Ambient atmospheric pressure: 80KPa~110KPa Underground coal mines with gas or coal dust explosion hazards
18.Dust collection scope: all dust and respirable dust.
Related article
-
FT - FZ5: All - in - One Negative Oxygen Ion Monitoring Station for Sanatoriums
2025-03-25 -
Small Automatic Weather Station: The Future of Distributed Meteorological Monitoring
2025-10-11 -
Forestry Weather Station: Your All-in-One Fire Risk Sentinel in the Woods
2024-12-09 -
Power Quality Measurement Monitoring Multiple Electrical Parameters
2026-03-11 -
Multifunctional meteorological monitoring equipment for ten-element weather stations
2024-07-02 -
Scenic anion weather monitoring system core function
2024-08-07 -
Advantages of Small automatic weather station
2024-09-03 -
Odor gas detector On-site Monitoring of Odorous Pollutants in Compliance with the GB14554 Standard
2026-10-19


Get a Free Quote